Product Description
Power/Energy Monitoring > Single Circuit > H80xx Enercept Series > Modbus. Enhanced Data, Modbus. 3 Phase. 800A. Large CT. The Enercept H8036 is an innovative three-phase networked (Modbus RTU) power transducer that combines electronics and high accuracy industrial grade CTs in a single package. The need for external electrical enclosures is eliminated, greatly reducing installation time and cost. The Enercept Enhanced Data Stream transducers output 26 energy variables including kW, kWh, volts, amps, and power factor, making them ideal for power monitoring and diagnostics. Color-coordination between voltage leads and CTs makes phase matching easy. Additionally, these transducers automatically detect and compensate for phase reversal, eliminating the concern of CT load orientation. Up to 63 transducers can be daisy-chained on a single RS-485 network. APPLICATIONS: Energy managing & performance contracting. Submetering for commercial tenants. Activity-based costing in commercial and industrial facilities. Real-time power monitoring. The world’s most cost-effective meter. Monitor energy parameters (kW, kWh, kVAR, PF, Amps, Volts) at up to 63 locations on a single RS-485 network...greatly reduces wiring time and cost. Fast split-core installation eliminates the need to remove conductors...saves time and labor. Precision electronics and current transformers in a single packageâ€"reduces the number of installed componentsâ€" huge labor savings. Smart electronics eliminate CT orientation concernsâ€"fast trouble-free installation. ±1% total system accuracy, (10% to 100% of CT rating). SPECIFICATIONS: Input Primary Voltage 208 to 480VAC RMS††. Number of Phases Monitored One to Three. Frequency 50/60Hz. Primary Current Up to 2400 amps cont. per phase††. Internal Isolation 2000VAC RMS. Insulation Class 600VAC RMS†††. Temperature Range 0° to 60°C (32° F to 140°F), 50°C (122°F) for 2400A. Humidity Range 0 - 95% non-condensing. Systems Accuracy ±1% of reading from 10% to 100% of the rated current of the CTs...accomplished by matching the CTs with a meter and calibrating them as a system. Output Physical Characteristics RS-485, 2 wire + shield Baud Rate 9600, 8N1 format. Protocol Modbus RTU**(*). ** Other protocols available. Please consult factory.††Contact factory to interface for voltages above 480VAC or current above 2400 Amps.†††Do not apply 600V Class current transformers to circuits having a phase-to-phase voltage greater than 600V, unless adequate additional insulation is applied between the primary conductor and the current transformers. Veris assumes no responsibility for damage of equipment or personal injury caused by products operated on circuits above their published ratings.. Veris. Veris Industries. H8036-0800-4.